Your Trusted Partner for High-Quality Valve Solutions

Cast Steel Gate Valve

National Standard Cast Steel Gate Valve

Cast Steel Gate Valve

Material:WCB, LCB, WC6, CF8, CF8M, CF3, CF3M

Size Range:2″ to 24″ 

Connection Options:Flanged, Threaded (NPT, BSP), Butt Weld, Socket Weld

Working Pressure:Class 150 to Class 1500 (up to 2,500 psi / 172 bar)

Working Temperature:-29°C to 425°C

Sealing Options:Metal-to-Metal, Resilient Seat, Graphite, PTFE

Manufacturing Method:Cast, Forged, Machined

Applicable Medium:Water, Oil, Gas, Steam, Chemical Fluids

Manufacturing Standard:API 600, API 602, ASME B16.34, BS 5163, DIN 3352

Product Overview

The Flanged Steel American Standard Gate Valve is designed for use with ANSI Class 150-600, PN 2.0-16.0 MPa, and JIS 10-20K standards. It is suitable for pipelines operating within temperatures of -25°C to 425°C for carbon steel and -40°C to 500°C for stainless steel, and is used to either open or close the flow of medium within the system. Depending on the material selection, this gate valve is compatible with media such as water, steam, oil, nitric acid, acetic acid, strong oxidizers, and urea. The valve is available in manual, bevel gear, and electric drive configurations, making it versatile for various applications.

Product Features

Full Port Flow: Provides an unobstructed flow path, resulting in minimal pressure drop when fully open.

Reliable Sealing: Metal-to-metal or resilient seating options provide tight sealing, minimizing leakage.

Corrosion Resistant: Manufactured from materials such as stainless steel, cast iron, and bronze for excellent corrosion resistance.

Versatile Connection Options: Available in flanged, threaded, butt weld, and socket weld connections to accommodate a variety of piping systems.

Durable Construction: Forged or cast body for enhanced strength and extended service life.

Manual, Gear, or Actuated Operation: Can be operated manually using a handwheel, by a gearbox, or automated with electric or pneumatic actuators.


Cast Steel Flanged Gate Valve Diagram

Specification Parameters

Structural Length Standard:
According to ASME B16.10, DIN 3202, BS EN 558

Connection Forms Standards:
Flanged per ASME B16.5, Threaded (NPT, BSP) per ANSI/ASME B1.20.1, Butt Weld per ASME B16.25, Socket Weld per ASME B16.11

Available Sizes (Caliber):
2″, 3″, 4″, 6″, 8″, 10″, 12″, 14″, 16″, 18″, 20″, 24″

Pressure-Temperature Rating:
Class 150, 300, 600, 900, 1500 as per API 600 and ASME B16.34

Pressure Range:
Up to 2,500 psi depending on size and material

Temperature Range:
-29°C to 425°C depending on material and sealing options


Performance parameters

Nominal pressurePN(MPa) case test pressure(MPa) Sealed
Sealed (liquid) Seal (gas)
1.6 2.4 1.8 0.6 1.8
2.5 3.8 2.8 0.6 2.8
4.0 6.0 4.4 0.6 4.4
6.4 9.6 7.0 0.6 7.0
10.0 15.0 11.0 0.6 11.0
16.0 24.0 18.0 0.6 18.0

Suitable medium and applicable temperature

Shell material Suitable media Applicable temperature (℃)
Carbon steel (C type) Water, steam, oil ≤425
Chromium nickel titanium steel (P type) Nitric acids ≤200
Chrome nickel molybdenum titanium steel (R type) Acetic acid ≤200
Chrome-molybdenum steel (type I) Water, steam, oil ≤550

The main part material

Body, bonnet Valve plate, seat Valve stem Stem nut filler Handwheel
Carbon steel High-quality carbon steel + carbide or stainless steel Chrome stainless steel Aluminum bronze Graphite asbestos packing Malleable iron
Chromium nickel titanium steel Stainless steel, stainless steel + cemented carbide Chrome nickel-titanium stainless steel Aluminum bronze Teflon Malleable iron
Chromium nickel molybdenum titanium steel Stainless steel, stainless steel + cemented carbide Chrome nickel-titanium stainless steel Aluminum bronze Teflon Malleable iron
Chrome-molybdenum steel Alloy steel + Carbide Chrome-molybdenum steel Aluminum bronze Flexible asbestos Malleable iron
The main shape and connection dimensions
Nominal diameter The main dimensions and connection dimensions
L D D1 D2 b Z-d H D0
Z41H-16C
15 130 95 65 45 14-2 4-Φ14 170 120
20 150 105 75 55 14-2 4-Φ14 190 140
25 160 115 85 65 14-2 4-Φ14 205 160
32 180 135 100 78 16-2 4-Φ18 270 180
40 200 145 110 85 16-3 4-Φ18 310 200
50 250 160 125 100 16-3 4-Φ18 358 240
65 265 180 145 120 18-3 4-Φ18 373 240
80 280 195 160 135 20-3 8-Φ18 435 280
100 300 215 180 155 20-3 8-Φ18 500 300
125 325 245 210 185 22-3 8-Φ18 614 320
150 350 280 240 210 24-3 8-Φ23 674 360
200 400 335 295 265 26-3 12-Φ23 811 400
250 450 405 355 320 30-3 12-Φ25 969 450
300 500 460 410 375 30-3 12-Φ25 1145 580
350 550 520 470 435 34-4 16-Φ25 1280 640
400 600 580 525 485 36-4 16-Φ30 1452 640
Z41H-25
15 130 95 65 45 16-2 4-Φ14 170 120
20 150 105 75 55 16-2 4-Φ14 190 140
25 160 115 85 65 16-2 4-Φ14 205 160
32 180 135 100 78 18-2 4-Φ18 270 180
40 200 145 110 85 18-3 4-Φ18 310 200
50 250 160 125 100 20-3 4-Φ18 358 240
65 265 180 145 120 22-3 8-Φ18 373 240
80 280 195 160 135 22-3 8-Φ18 435 280
100 300 230 190 160 24-3 8-Φ23 500 300
125 325 270 220 188 28-3 8-Φ25 614 320
150 350 300 250 218 30-3 8-Φ25 674 360
200 400 360 310 278 34-3 12-Φ25 811 400
250 450 425 370 332 36-3 12-Φ30 969 450
300 500 485 430 390 40-4 16-Φ30 1145 580
350 550 550 490 448 44-4 16-Φ34 1280 640
400 600 610 550 505 48-4 16-Φ34 1452 640

Specification Applications

Industries
  • Oil & Gas Industry: Used in pipelines for controlling the flow of crude oil, natural gas, and other hydrocarbon products.
  • Power Plants: Ideal for steam and condensate systems requiring reliable shutoff at high temperatures.
  • Water Treatment Plants: Used to control the flow in both potable and wastewater treatment processes.
  • Chemical Industry: Suitable for handling a wide range of aggressive chemicals in processing applications.
  • HVAC Systems: Applied in heating and cooling systems for controlling the flow of water or steam.
Specific Applications
  • Pipeline Isolation: Used for isolating sections of piping for maintenance and safety.
  • Steam Lines: Suitable for high-temperature steam isolation in power generation and industrial applications.
  • Flow Control in Storage Tanks: Provides shutoff capabilities in storage tanks containing oil, gas, or chemicals.
  • Fire Suppression Systems: Used in fire mains and sprinkler systems for flow control and system isolation.
Installation Instructions
  • Verify the valve size, pressure rating, and material compatibility with the pipeline and medium before installation.
  • Ensure the pipeline is depressurized before installation to prevent accidents.
  • Install the valve in a fully open position to avoid damage to the gate and seat during installation.
  • Use appropriate sealing materials (e.g., PTFE tape or gaskets) to ensure a leak-proof connection.
  • Tighten flange bolts evenly to prevent distortion of the valve body.
  • Test the valve for proper operation after installation, including checking for any signs of leakage or misalignment.

Valve Actuation

Process Optimization

Precision Engineering

Pipeline Solutions

Industrial Valves

Flow Control

Related Products

Get In Touch

Discover our premium valve solutions and boost your efficiency. Contact
us now to find out how we can support your needs with top-quality
products and exceptional service.