Design and manufacturing:GB/T 12235, ASME B16.34, IEC 60534
The structural length: GB/T 12221, ASME B16.10
Connection forms:HG/T 20592-20605, GB/T 9112-9124, ASME B16.5
Inspection and test:GB/T 13927, API 598, IEC 60534-4
Caliber:Specified in the selected configuration datasheet
Pressure temporature level:ASME B16.34, GB/T 12224
Drive mode: Electric Actuated
Pressure: Specified in the selected configuration datasheet
The MacoTango Electric Double-Seat Control Valve regulates flow through a double-seat globe-valve arrangement.
The two seating areas can reduce the net fluid force compared with an equivalent unbalanced single-seat arrangement. Both seats must work together through the operating temperature range, so shutoff requirements should be stated explicitly rather than inferred from the number of seats.
The electric actuator must provide the required linear thrust and positioning duty for both normal regulation and closure. Temperature changes should be included when defining acceptable shutoff.
Consider this arrangement for process regulation where capacity and fluid-force balance are priorities. A demanding isolation requirement may call for a different trim or a separate shutoff valve.
| Trim arrangement | Double-seat globe trim |
|---|---|
| Control function | Modulating |
| Drive | Electric |
| Shutoff basis | Model-specific leakage test, not seat count |
| Actuation | Electric; supply and command interface selected for the assembly |
| Size and pressure class | Specified in the configuration datasheet for the selected model |
| Operating temperature | Limited by the complete material, seat, seal and actuator arrangement |
A configuration-specific PDF is not currently available. Ask for a datasheet with your process conditions and connection requirements.
For a configuration-specific quotation, send the following information:
We will confirm the final configuration and datasheet against the stated duty before order acceptance.
No. Two seating interfaces do not inherently give tighter shutoff. Specify the leakage test and operating conditions required for the application.
That depends on the required isolation performance. Verify the leakage requirement; use separate isolation where the process needs it.
The MacoTango Electric Double-Seat Control Valve regulates flow through a double-seat globe-valve arrangement.
The two seating areas can reduce the net fluid force compared with an equivalent unbalanced single-seat arrangement. Both seats must work together through the operating temperature range, so shutoff requirements should be stated explicitly rather than inferred from the number of seats.
The electric actuator must provide the required linear thrust and positioning duty for both normal regulation and closure. Temperature changes should be included when defining acceptable shutoff.
Consider this arrangement for process regulation where capacity and fluid-force balance are priorities. A demanding isolation requirement may call for a different trim or a separate shutoff valve.
| Trim arrangement | Double-seat globe trim |
|---|---|
| Control function | Modulating |
| Drive | Electric |
| Shutoff basis | Model-specific leakage test, not seat count |
| Actuation | Electric; supply and command interface selected for the assembly |
| Size and pressure class | Specified in the configuration datasheet for the selected model |
| Operating temperature | Limited by the complete material, seat, seal and actuator arrangement |
© 2026 MacoTango Valve. All Rights Reserved.